Parameter No. 93 - CO Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
• 0 no action
• 1 open relay
• 2 close relay
Parameter No. 94 - Heat Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
• 0 no action
• 1 open relay
• 2 close relay
Parameter No. 120 - Factory Reset
Reset to factory default settings and removed from the Z-Wave network.
The parameter is Advanced and may be hidden under the Advanced tag.
Values size: 1 Byte
Default value: 0
Values & descriptions:
• 0 - Don’t do Factory reset
• 1 - Do the Factory reset