RECOMMENDATION: Place the antenna as far away as possible from metal elements as they
can cause signal interference.
RECOMMENDATION: Connect the Device using solid single-core wires with increased
insulation heat resistance not less than PVC T105°C (221°F).
RECOMMENDATION: For inductive appliances that cause voltage spikes during switching
on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 µF /
100 Ω / 1/2 W / 600 VAC) should be connected parallel to the appliance.
Connect the load circuit to the Device I and O terminals.
If you are using AC power supply for the Device, connect the Live wire to the Device L terminal,
and the Neutral wire to the N terminal as shown on Fig. 1. Connect a switch or a push-button to
the Device SW terminal and the Live wire.
If you are using 24-48 V DC power supply (Fig. 2), connect the + wire to the + and the GND
wire to the terminals of the Device.
If you are using stabilized 12 V DC power supply (Fig. 3), connect the + wire to the 12V+
terminal, instead to the + terminal. Connect the switch/push-button to the “SW” terminal and
the GND wire.