34
Parameter Description
Parameter Description
5.2 Range of the Output Frequency (P.1, P.2, P.18)
P.1 “Maximum frequency”
P.2 “Minimum frequency”
P.18 “High-speed maximum
frequency
R
e
l
a
t
e
d
p
a
r
a
m
e
t
e
r
s
P.13 Starting frequency
The upper limit and the lower limit of the output frequency can be restricted.
Parameter Factory Setting Setting Range Remarks
--- zH021~0 zH021 1
--- zH021~0 zH0 2
--- zH056~021 zH021 81
<Setting>
If the target frequency P.2, the steady output frequency = P.2.
If P.2
target frequency P.1 (P.18), the steady output frequency = the target frequency.
If P.1 (P.18)
target frequency, the steady output frequency = P.1.
Note: 1. The maximum frequency and the high-speed maximum frequency are interrelated. P.1 must be used (the
setting range of P.1 is 0~120Hz) if the target upper limit frequency is in the range of 0~120Hz. P.18 must
be used (the setting range of P.18 is 120~650Hz) if the target upper limit frequency is in the range of
120~650Hz.
2. If P.1
P.2, the steady output frequency will be clamped to P.1.
3. The set frequency value can not exceed the value of P.1.
P.1(P.18)
P.2
Output
frequency
Hz
Setting frequency (Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2-021 Series and is the answer not in the manual?

Shihlin electric SS2-021 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSS2-021 Series
CategoryInverter
LanguageEnglish

Related product manuals