94
Parameter Description
Parameter Description
Para-
meter
Termi
nal
Factory
Setting
Setting
Range
Value Function Name Function Description Remarks
5 AU
At the external mode,
combined mode 2 or
combined mode 4,
the inverter target
frequency is set by
the signal input
across terminal 4-5
when AU is on.
Please refer
to P.39
6 OH (Note 3)
81 M1 3
0~40
,43
7 MRS
When MRS is turned
on, the output
terminates.
8 RT
When RT is on, the
characteristics are the
same as the second
function.
Please refer
to P.44
9
EXJ
˄External JOG˅
At the external mode,
the target frequency
is set by P.15
and the
acceleration/
deceleration time is
set by P.16
when EXJ
is on (Note 4).
10 STF+EXJ
11 STR+EXJ
12 STF+RT
82 M2 4
0~41
,43
13 STR+RT
14 STF+RL
15 STR+RL
16 STF+RM
17 STR+RM
18 STF+RH
19 STR+RH
20 STF+RL+RM
21 STR+RL+RM
22 STF+RT+RL
23 STR+RT+RL
24 STF+RT+RM
25 STR+RT+RM
26 STF+RT+RL+RM
83 STF 0
0~40
,43
27 STR+RT+RL+RM
Multiplexed function
The
multiplexed
function is
the complex
of several
basic
functions.
It means
that one
multiplexed
terminal can
be used to
realize
several
basic
functions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SS2-021 Series and is the answer not in the manual?

Shihlin electric SS2-021 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSS2-021 Series
CategoryInverter
LanguageEnglish

Related product manuals