1.
2.
3.
4.
5.
6.
Configuring IP Settings
Go to the Utility tab of the control software to manage the IP configurations of each network interface. By default, they are set
to Automatic (DHCP) mode. DHCP mode enables the devices to accept IP settings from a DHCP server, or automatically fall
back to Link-Local settings when no DHCP is available. To manually set the IP address of an interface, select Manual (Static).
The MXW control software coordinates IP updates across the entire system of devices. To configure the IP properties, follow
these steps:
Open the MXW control software from the Shure Web Device Discovery app.
Go to the Utility tab.
Adjust IP settings for each device by selecting the Device Properties.
After adjustments have been made, select Add Updates. This saves the settings to the changes queue.
Repeat for any additional components.
To send updates to the devices, select Apply All to the Pending Changes field of the Utility page.

Table of Contents

Other manuals for Shure Microflex MXWNCS8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shure Microflex MXWNCS8 and is the answer not in the manual?

Shure Microflex MXWNCS8 Specifications

General IconGeneral
BrandShure
ModelMicroflex MXWNCS8
CategoryMicrophone system
LanguageEnglish

Related product manuals