Adjustment Commands
COMMAND ACTION RESULT
Rudder sensitivity: increase P
ILOT or NAV MODE.
Press Set Key twice.
Press Green Key.
Autopilot will steer with a “harder”
turn to correct course deviations,
causing a shorter correction, but
more overshoot of the intended
course. Changes will only affect
the current speed (fast or slow)
sensitivity setting.
Rudder sensitivity: decrease In P
ILOT or NAV MODE.
Press Set Key twice.
Press Red Key.
Autopilot will steer with a “softer”
turn to correct course deviations,
causing a longer correction
distance but less overshoot of the
intended course. Changes only
affect the current speed (fast or
slow) sensitivity setting).
Counter-Rudder sensitivity:
decrease
In P
ILOT or NAV MODE.
Press Set Key three times.
Press the Red Key.
Autopilot will steer with a “harder”
turn to correct course deviations,
causing a shorter correction, but
more overshoot of the intended
course. Changes will only affect
the current speed (fast or slow)
sensitivity setting.
Counter-Rudder sensitivity:
increase
In Pilot or Nav Mode.
Press Set Key three times.
Press the Green Key.
Autopilot will steer with a “softer”
turn to correct course deviations,
causing a longer correction
distance but less overshoot of the
intended course. Changes only
affect the current speed (fast or
slow) sensitivity setting.
Cross Track Error Sense:
change
In N
AV MODE. Press Flush
Key. Press Green Key.
Autopilot will steer properly along
course line when Cross Track Error
Sense is correct. See Navigation
interface section for more
information.
Set-up Routine Pilot is OFF. Press and hold
Flush Key. Press and hold
Pilot Key.
Set-up Procedure begins.