3    PRODUCT DESCRIPTION 
26
  OPERATING INSTRUCTIONS  |  AFS60/AFM60 PROFINET  8015078/145N/2019-05-24 |  SICK STEGMANN 
  Subject to change without notice 
Data type 
41h  =  Byte 
42h  =  WORD 
43h  =  DOUBLE WORD 
Number of values that follow 
Table 26:  Structure  of the parameter value 
3.5.2  Structure of the parameter Response 
A Response parameter has the following structure: 
Request identification; should be 
unique for each request 
Access type: 
01h  =  Parameter request 
successful 
02h  =  Parameter change 
successful 
81h  =  Parameter request failed 
82h  =  Parameter change failed 
Returns the same value that the 
request contains 
Number of parameters accessed 
00h  reserved 
01h … 27h 
28h … 28h reserved 
Includes the value of the 1. 
parameter or an error message 
Includes the value of the nth 
parameter or an error message 
Table 27:  Structure  of the parameter Response 
 
Data type 
0Ah  =  OCTET  STRING 
41h  =  Byte 
42h  =  WORD 
43h  =  DOUBLE WORD 
44h  =  Error message 
Number of values that follow 
Table 28:  Structure  of the parameter value