PRODUCT DESCRIPTION  3   
8015078/145N/2019-05 -24 | SICK STEGMANN  OPERATING INSTRUCTIONS  |  AFS60/AFM60 PROFINET 
37
 
Subject to change without notice 
Code sequence 
1 =  counterclockwise 
0 =  Clockwise 
Class 4  functionality 
0 =  Inactive 
1 =  Active 
G1_XIST1 preset control 
0 =  Active 
1 =  Inactive 
Scaling function control 
0 =  Inactive 
1 =  Active 
Alarm channel control 
0 =  Inactive 
1 = Active 
Compatibility mode 
0 =  V3.1, backward compatible 
1 =  V4.1, not backward compatible 
Table 36:  Bits of the index 65.001.01 
3.6  Configurable functions 
The AFS60/AFM60 PROFINET is configured using the configuration tool for a PLC (e.g. 
Siemens TIA Portal V13). 
NOTE 
After changing the parameter, the encoder must remain energized for at least 1 sec. to 
save the parameter change(s). 
 
3.6.1  Code sequence 
The code sequence defines the direction of rotation, viewed on the shaft, in which the 
position value increases. 
NOTE 
The parameter can only be configured if the class 4 functionality is activated. 
 
3.6.2  Class 4 functionality 
The class 4 functionality is activated from the factory. This parameter permits or 
prevents changes to the parameters Code sequence, Scaling and Implementation of 
the preset. 
If the parameter is deactivated (disable), the settings for the following parameters are 
fixed: 
  Code sequence = clockwise 
  Scaling = off 
  No preset via telegram or preset pushbutton possible