7 Technical data
7.1 Data sheet
NOTE
T
he following table only contains details on the safety light curtain that are not included
in the underlying operating instructions.
Table 2: General system data
Minimum Typical Maximum
Protective field height, depending on
t
ype
600, 900, and 1,200 mm
Resolution (detection capability) 20 mm
Protective field width 0 m … 15.9 m 0 m … 17.6 m
1)
Enclosure rating (EN 60529) IP 66
2)
Equipment group/category II
X II 2 G Ex db IIB T6 Gb
X II 2 D Ex tb IIIC T56°C Db
Ex db IIB T6
Ex tb IIIC T56°C Db IP6X
Weight Depending on the protective field height, see "T
able of
weights", page 24
1)
If you are using the full protective field width, check to see if the orange LED lights up (cleaning or align‐
ment nece
ssary). The system still has a reserve of 30 %.
2)
In order to achieve enclosure rating IP 66, washers must be used for the fixing screws on the enclosure
cover.
7.2 Table of weights
Table 3: Weight of sender and receiver
Protective field height [mm] Weight [kg]
1)
s S
ender r Receiver
600 29.92 29.95
900 38.57 38.6
1200 47.22 47.25
1)
Tolerance: ± 50 g.
7 TECHNICAL DATA
24
O P E R A T I N G I N S T R U C T I O N S | C4000 Fusion Ex 8022867/2019-03-04 | SICK
Subject to change without notice