2 Safety information
In addition to the notes in the underlying operating instructions for the C4000 Fusion
s
afety light curtain, please observe the following points when using the C4000
Fusion Ex safety light curtain.
2.1 Correct use
The C4000 Fusion Ex safety light curtain is an electro-sensitive protective device (ESPE)
and is suit
able for the following applications:
•
Hazardous point protection
•
Access protection
•
Hazardous area protection
The C4000 Fusion Ex safety light curtain is suitable for use in enclosed spaces only. It
ha
s UL/cUL certification for the following hazardous areas defined in the National Elec‐
trical Code® and Canadian Electrical Code®:
•
Class I, Groups C, D
•
Class II, Groups E, F, G
•
Class III
The C4000 Fusion Ex safety light curtain also complies with these standards:
EN 60079-0:2012/A11:2013/
IEC 60079-0 Edition 6.0, EN 60079-1:2014/
IEC 60079-1 Edition 7.0, EN 60079-31:2014/IEC 60079-31 Edition 2.0 and is certi‐
fied for the following hazardous areas:
•
X II 2 G Ex db IIB T6
•
X II 2 D Ex tb IIIC T56°C Db IP6X
•
Ex db IIB T6
•
Ex tb IIIC T56°C Db IP6X
DEMKO 14 ATEX 1315X
IECEx UL 14.0034X
The C4000 Fusion Ex safety light curtain does not emit any paint wetting impairment
sub
stances or volatile silicones and does not expel any fixed parts or materials into the
surrounding area.
Foreseeable misuse
The C4000 Fusion Ex safety light curtain is not suitable for the following applications:
•
Outdoors
•
Under water
•
In areas where there may be flying sparks
SAFETY INFORMATION 2
8022867/2019-03-04 | SICK O P E R A T I N G I N S T R U C T I O N S | C4000 Fusion Ex
5
Subject to change without notice