Technical Information Chapter 4
CLV61x
Electrical installation
8015592/ZNI9/2017-06-13 © SICK AG · Germany · All rights reserved · Subject to change without notice 33
4.7.6 Wiring the "Sensor 2" Switching Input in the CDB620-001 Connection Module
Power fed to the input starts the assigned
function, e.g. stop of reading clock.
(default setting: logic not inverted [active high],
debouncing 10 ms)
Optodecoupled, reverse polarity protected
Can be wired with the PNP output of a sensor
SensGND reference potential valid for all
switching inputs
Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 32 V;
0.7 mA ≤ I
in
≤ 5 mA
Switching
behavior
Features
Electrical
values
6
1
10
5
11
15
CLV61xCDB620
PNP sensor
V
S
V
S
V
S
GND
SensGND
3.32 K
6.64 K
Sensor 2
V
in
U
IN
* = DC 10 V to 30 V
a) Sensor supplied by CDB620
b) Sensor connected electrically isolated/externally supplied
d) Switch connected electrically isolated/externally supplied
c) Switch supplied by CDB620
4
15
1
5
15
SGND
7
Shield
14
U
IN
*
13 Sens 2
Out
U
IN
*
GND
S3
e.g. photo-electric switch
CDB620
PNP sensor
V
S
GND
Connect the switch as shown in b)
15
SGND
7
Shield
14 U
IN
*
13 Sens 2
Out
U
IN
*
GND
S3
e.g. photo-electric
switch
Function assignment to "Sensor 2" switching input
via SOPAS ("Sensor/Input 2"):
- Start of reading clock
- Stop of reading clock
- Start teach-in matchcode/start code comparison
- Increment input
- if required further functions in the future
U
IN
*
CDB620
15 SGND
7 Shield
14
U
IN
*
13
Sens 2
GND
S3
ON
OFF
S3 : SGND-GND
ON
OFF
S3 : SGND-GND
ON
OFF
S3 : SGND-GND
V
S ext
Shield
D-Sub HD plug,
15-pin
GND
.
.
.
Shield
Shield
V
in
= max. 32 V
Ratings for "Sensor 2" switching input
SensGND
Switch S3: SGND-GND
ON: GND of the sensor connected to GND
of CDB620/CLV61x.
OFF: GND of the sensor connected to
SensGND of CDB620/CLV61x
(Sensor connected electrically isolated
to the CDB620/CLV61x).
Selected reference potential valid for all
switching inputs ("Sensor 1/2" and "In 1/2")
GND

Other manuals for SICK CLV61 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV61 Series and is the answer not in the manual?

SICK CLV61 Series Specifications

General IconGeneral
BrandSICK
ModelCLV61 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals