Chapter 3 Technical Information
CLV61x bar code scanner
16 © SICK AG · Germany · All rights reserved · Subject to change without notice 8015592/ZNI9/2017-06-13
Mounting
3.3 Mounting the CDB620-001 or CDM420-0001 Connection
Module
The mounting location for the connection module (distance to CLV61x) depends on the
physical design (RS-232) of the both serial data interfaces AUX and HOST and the transmis-
sion rates used:
Recommended cable length between CLV61x and connection module:
Max. 5 m when using max. data transmission rate 115.2 kBd of the HOST interface.
(fixed data transmission of AUX interface: 57.6 kBd)
For detailed information on mounting and the electrical installation of the connection mod-
ule, please see:
"CDB620 connection module" operating instructions (part no. 8012119, Ger./Engl.
version) e.g. via www.sick.com/CDB
"CDM420-0001 connection module" operating instructions (part no. 8010004, Ger./
Engl. version) e.g. via www.sick.com/CDM
The corresponding operating instructions are enclosed in printed form with the connection
modules.