Figure 20: Sender and receiver must not be installed such that they are rotated 180° relative to
e
ach other
Prerequisites
Pr
oject planning is completed.
Assembly is carried out according to the project planning.
Dangerous condition of the machine is and remains switched off during mounting.
The outputs of the device do not affect the machine during mounting.
Only use SICK-approved brackets for mounting.
Take appropriate measures for vibration damping if vibration and shock specifica‐
tions exceed the values and test conditions specified in the data sheet.
Notes on mounting
b Mount t
he sender and receiver on a level surface (1).
1
b
Mount t
he sender and receiver such that a right-angled protective field is estab‐
lished, i.e. when mounted vertically at the same height. For minor adjustments
during alignment, the sender and receiver can be adjusted longitudinally in the
brackets (2).
5 MOUN
TING
32
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Ex II 3GD 8021796/1DCM/2022-10-27 | SICK