6.4.5.1.1 Operating example via display: MF Function
Function of the multifunctional input MF (“MF Function”)
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → MF Input
→ MF Function
→ Teach
/ until the desired function of the multifunctional
input MF is displayed
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
Teach
6.4.5.2 External teach (“Teach”)
Description
In the “Teach” operating mode you can use various teach functions by creating signal
levels of various lengths at the multifunctional input. The timing tolerance for all teach
functions is +/- 20 ms.
The following functions are available:
Teach function Time
[ms]
Explanation in chap.
Move last teach point + 10 mm 60
Move last teach point - 10 mm 120
Switching off laser 200 see "Switch the laser on/off", page 69
Switching on laser 300 see "Switch the laser on/off", page 69
Distance to object for Q
1
: Teach Q 400 see "Operating examples via display: “Dis‐
tance to object” (“DtO”) switching mode",
page 24
Distance to object for Q
1
: Teach Q not 500 see "Operating examples via display: “Dis‐
tance to object” (“DtO”) switching mode",
page 24
Switching window for Q
1
: Teach Q near 600 see "Operating examples via display:
“Switching window” (“Window”) switching
mode ", page 29
Switching window for Q
1
: Teach Q far 700 see "Operating examples via display:
“Switching window” (“Window”) switching
mode ", page 29
ObSB (Background) for Q
1
: Teach Q 800 see "Operating examples via display:
“Object between sensor and background”
(ObSB) switching mode", page 33
ObSB (Background) for Q
1
: Teach Q not 900 see "Operating examples via display:
“Object between sensor and background”
(ObSB) switching mode", page 33
Switching window for Q
1
: Centering
teach
1
1000 see "Centering function or center displace‐
ment", page 67
Distance to object for Q
2
: Teach Q 1100 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
Distance to object for Q
2
: Teach Q not 1200 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
OPERATION 6
8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
59
Subject to change without notice