Teach function Time
[ms]
Explanation in chap.
Switching window for Q
2
: Teach Q near 1300 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
Window for Q
2
: Teach Q far 1400 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
ObSB (Background) for Q
2
: Teach Q 1500 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
ObSB (Background) for Q
2
: Teach Q not 1600 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
Switching window for Q
2
: Centering
teach
1
1700 see "Centering function or center displace‐
ment", page 67
Q
A
with 4-20 mA for Q
2
: Teach 4 mA 1800 see "Operating examples via display: Scal‐
ing the analog output with respect to the
distance value output", page 52
Q
A
with 4-20 mA for Q
2
: Teach 20 mA 1900 see "Operating examples via display: Scal‐
ing the analog output with respect to the
distance value output", page 52
Q
A
with 0-10 V for Q
2
: Teach 0 V 2000 see "Operating examples via display: Scal‐
ing the analog output with respect to the
distance value output", page 52
Q
A
with 0-10 V for Q
2
: Teach 10 V 2100 see "Operating examples via display: Scal‐
ing the analog output with respect to the
distance value output", page 52
Q
A
(4-20 mA or 0-10 V): Centering teach
1
2200 see "Centering function or center displace‐
ment", page 67
Switch off the MF confirmation 2300 see "Confirmation of the teach via MF via
output Q
1
(“Confirm teach”)", page 60
Switch on the MF confirmation 2400 see "Confirmation of the teach via MF via
output Q
1
(“Confirm teach”)", page 60
Signal level warning (SLW) Q
1
: Teach Q 2500 see "Operating examples via display: “Q
1
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
1
: Teach Q
not
2600 see "Operating examples via display: “Q
1
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
2
: Teach Q 2700 see "Operating examples via display: “Q
1
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
2
: Teach Q
not
2800 see "Switching mode for Q
2
(“ModeQ
2
”)",
page 49
Reset Wi-Fi settings to factory condition
2
3800
Laser off > 5000 see "Switch the laser on/off", page 69
1
Centering limits. The near and far points that have been moved via centering must always lie within the
value range limits. Moved points must always be evaluated by the user.
2
Can be used only in variants with a Wi-Fi interface. Function available only in the first 60 seconds after
switching on the device.
6.4.5.3 Confirmation of the teach via MF via output Q
1
(“Confirm teach”)
Description
With this function, a confirmation can be output via the switching output Q
1
for each
teach via multifunctional input.
6 OPERATION
60
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK