Service Physical
port
Logical
port
Encrypted Authenti‐
cated
Default
status
Description
DHCP
server
USB TCP port
67
No No Listening Only listens on USB. Ena‐
bles automatic IP config‐
uration for RNDIS
SSH server P3 TCP port
22
Yes Yes Not used Used for device repair
TCP client P3 TCP con‐
figurable
port
N/A N/A Not used Used by the Nova 2D
SensorApp, tool TCP Cli‐
ent
TCP server P3 TCP con‐
figurable
port
N/A N/A Not used Used by the Nova 2D
SensorApp, tool TCP Cli‐
ent
EtherNet/IP P1, P2 TCP port
44818
UDP
ports
161,
2222,
44818,
68
No No Not used Used by the Nova 2D
SensorApp if Fieldbus
with Ethernet/IP commu‐
nication is set up
PROFINET P1, P2 UDP
ports
161,
34964,
49153
No No Not used Used by the Nova 2D
SensorApp if Fieldbus
with Ethernet/IP commu‐
nication is set up
In addition, custom SICK AppSpace Software can be used to enable additional network
services. This is described in the LUA API.
2.4
Limitation of liability
Relevant standards and regulations, the latest technological developments, and our
many years of knowledge and experience have all been taken into account when
compiling the data and information contained in these operating instructions. The
manufacturer accepts no liability for damage caused by:
■
Non-adherence to the product documentation (e.g., operating instructions)
■
Incorrect use
■
Use of untrained staff
■
Unauthorized conversions or repair
■
Technical modifications
■
Use of unauthorized spare parts, consumables, and accessories
2.5 Modifications and conversions
NOTICE
Modifications and conversions to the device may result in unforeseeable dangers.
Interrupting or modifying the device or SICK software will invalidate any warranty claims
against SICK AG. This applies in particular to opening the housing, even as part of
mounting and electrical installation.
2 SAFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | Inspector85x 8028305//2023-05 | SICK
Subject to change without notice