6.4 Connecting
6.4.1 Connecting the product electrically
Important information
NOTICE
Observe the wiring instructions, see "Wiring instructions", page 26.
Approach
1. Ensure the voltage supply is not connected.
2. Connect the product according to the connection diagram.
Further topics
Connections and pin assignment
6.4.2 Voltage supply
Prerequisites
Configure the circuits connected to the device as ES1 circuits or as SELV circuits
(SELV = Safety Extra Low Voltage). The voltage source meets the requirements of
ES1 (EN62368-1) or SELV (EN60950-1).
Required power output of the voltage source: at least 48W
To ensure protection against short-circuits/overload in the customer’s supply
cables, choose and implement wire cross-sections in accordance with the appli‐
cable standards.
For a supply voltage of DC 24V ±20%, protect the cables with a separate fuse.
The type of fuse required depends on the cable used (typically e.g. cable M12
17-pin with 2A fuse, cable M12 5-pin with 4A fuse). Install the fuse in the supply
circuit at the start of the supply cable.
6.4.3 Fieldbus connection principle
Figure 15: Connection principle for fieldbus
1
PLC (Programming Logic Controller)
2
Fieldbus (Profinet, EtherNet/IP)
6 ELECTRICAL INSTALLATION
32
O P E R A T I N G I N S T R U C T I O N S | Inspector85x 8028305//2023-05 | SICK