Display LED (color) Description
BF/ERR/NS PROFINET: Bus failure (BF)
o
No error
Ö (Red)
No data exchange
O (Red)
No configuration, low speed physical
link, or no physical link
Ethernet/IP: Network status (NS)
O (Green)
Device has an IP address and a CIP
connection
Ö (Green)
No connection, device has an IP
address, but no CIP connection
Ö (Red)
Warning, connection time out, reset
by performing a reset or establishing
a new connection
O (Red)
Error, IP address has already been
assigned to a different device
Ö Öo(Green, red, off)
Self-test when switching on
o
No supply voltage or no IP address
L/A P1 FB
O (Green)
Connected to network
(10/100MB/s)
O (Yellow)
Data transmission over the network
(10/100MB/s)
o
No fieldbus connection
L/A P2 FB
O (Green)
Connected to network
(10/100MB/s)
O (Yellow)
Data transmission over the network
(10/100MB/s)
o
No fieldbus connection
o = off; O = illuminated; Ö = flashing
3.4.4 Product features and functionality
The Inspctor85x is a 2D vision sensor that offers a rapid and flexible solution. The
Inspector85x is suitable for complex and demanding inspection tasks, including a wide
variety of industrial tasks thanks to its programmable interface.
Convenient functions such as function buttons, auto-setup, aiming laser, and a green
feedback LED reduce the amount of work required for training and installation.
The Dual-port fieldbus gives multi-channel Gigabit image output which enables
advanced throughput.
The microSD memory card can be used to store images or backup copies of parame‐
ters. Thanks to SICK's 4Dpro feature, the Inspector85x can be integrated into numerous
industrial networks.
PRODUCT DESCRIPTION 3
8028305//2023-05 | SICK O P E R A T I N G I N S T R U C T I O N S | Inspector85x
19