6.3 Connections and pin assignment
Overview
Figure 10: Connection overview
1
P1: Fieldbus Ethernet 1
2
P2: Fieldbus Ethernet 2
3
P3: GB Ethernet
4
X2: Power/External illumination/IO
5
X1: Power/serial interface/IO
Power/serial interface/IO
1
2
6 714
12
3
4
5
8
9
10
11
13
15
17
16
Figure 11: Male connector, M12, 17-pin, A-coded
PIN Signal Function
1 GND Ground
2 V
S
Supply voltage: DC 24V ±20%
3 – –
4 – –
5 TD+ (RS-422) Serial data interface (sender+)
6 TD- (RS-422)
TxD (RS-232)
Serial data interface (sender-)
7 TxD (RS-232) Serial service interface (sender)
8 RxD (RS-232) Serial service interface (receiver)
9 SensGND Ground digital inputs 1 and 2
10 Sensor 1 Digital input 1 (insulated)
11 RD+ (RS-422) Serial data interface (receiver+)
12 RD- (RS-422)
RxD (RS-232)
Serial data interface (receiver–)
13 IN/OUT 3 Digital input/output 3 (configura‐
ble)
14 IN/OUT 4 Digital input/output 4 (configura‐
ble)
15 Sensor 2 Digital input 2 (insulated)
16 IN/OUT 5 Digital input/output 5 (configura‐
ble)
17 IN/OUT 6 Digital input/output 6 (configura‐
ble)
6 ELECTRICAL INSTALLATION