Inspector850
Dimensions (L x
W x H)
143.4mm x 90mm x 46mm
7)
1)
Maximum length of cable: 10 m
2)
Maximum length of cable: 30 m
3)
Without load on digital outputs and power out.
4)
Ensure that the sum of power out current for external illumination and the output currents do not exceed
1050mA.
5)
When the cover is open, the device no longer conforms with the specified enclosure rating.
6)
Comply with the requirements to maintain the specified enclosure rating.
Prerequisites:
The optics protection hood must be screwed tightly onto the device.
The cover on the top of the device is closed.
The cables plugged into the electrical connections must be screwed tight. Electrical connections
that are not being used are sealed off with a protective cap.
7)
Housing only, without lens and optics protection hood.
11.3 Performance
Inspector850
Sensor resolution V2D8505xxxxxxxxxxx: 5megapixel (2464px x 2048px)
V2D8512xxxxxxxxxxx: 12megapixel (4096px x 3008px)
Scan/frame
rate
1)
30 Hz, at 5 megapixels resolution
15 Hz, at 12 megapixels resolution
1)
Maximum, lower at long exposure times. Image capture time only, does not include additional required
processing time.
11.4 Interfaces
Inspector850
Ethernet Protocol: TCP/IP
Function:
FTP
Data transmission rate: 10/100/1000Mbit/s
EtherNet/IP Function:
EtherNet/IP Dual Port
Data transmission rate: 10/100Mbit/s
PROFINET Function:
PROFINET Dual Port
Data transmission rate: 10/100Mbit/s
Optical displays 10 status LEDs
2 feedback LEDs of the VI83I illumination unit (green, red)
Operator interfa‐
ces
Web server
Configuration
software
Web GUI (SensorApp configuration), SICK AppManager (IP determination
and configuration, SensorApp installation), SICK AppStudio (programming)
Data storage and
retrieval
Image and data storage via external FTP
Inputs/outputs 2 x insulated inputs, physical, switching
6 x configurable inputs/outputs, physical, switching (4 on Power-I/O connec‐
tor, 2 on External illumination connector)