Power/External illumination/IO
21
4
3
5
Figure 12: Female connector, M12, 5-pin, A-coded
PIN Signal Description
1 GND Ground sensor
2 IN/OUT 8 Digital input/output (configurable)
3 V
out
switchable
1)
Switchable power out for external
illumination
4 IN/OUT 7 or Trigger external illumi‐
nation
Digital input/output (configurable)
or
Trigger for external illumination
5 V
S
Supply voltage
1)
The maximum output current is limited to 1.0A and can only be enabled if the internal illumination is
disabled. Ensure that the sum of output currents from all digital outputs and the power out do not exceed
1050mA.
Fieldbus Ethernet
3
2
4
1
Figure 13: Female connector, M12, 8-pin, X-coded
PIN Signal Description
1 TX+ Sender+
2 RX+ Receiver+
3 TX– Sender
4 RX– Receiver
GB Ethernet
5
4
6
32
8
1
7
Figure 14: Female connector, M12, 8-pin, X-coded
PIN Signal Description
1 TRD0_P Sender+/receiver+ 0
2 TRD0_N Sender–/receiver– 0
3 TRD1_P Sender+/receiver+ 1
4 TRD1_N Sender–/receiver– 1
5 TRD3_P Sender+/receiver+ 3
6 TRD3_N Sender–/receiver– 3
7 TRD2_N Sender–/receiver– 2
8 TRD2_P Sender+/receiver+ 2