EasyManua.ls Logo

SICK Inspector85 Series - Page 18

SICK Inspector85 Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Status LEDs
Display LED (color) Description
Ready
O (Green)
The device is switched on and ready
for use
O (Red)
Error
Ö (Green)
Device is not ready for use.
Reasons
Firmware update
Parameter change by the user
Parameter change by another
device (e.g., PLC)
O (Blue)
Device powers up
Result Red, green, blue, fuchsia,
yellow, aqua, white
Configurable by the user
Function Red, green, blue, fuchsia,
yellow, aqua, white
Configurable by the user
L/A P1 GbE Not used
L/A P2 GbE Not used
L/A P3 GbE
O (Green)
Connected to network
(10/100MB/s)
Ö (Green)
Data transmission over the network
(10/100MB/s)
O (Blue)
Connected to network (1GB/s)
Ö (Blue)
Data transmission over the network
(1GB/s)
o
No Ethernet connection
SF/RUN/MS PROFINET: System failure (SF)
o
No error
Ö (Red)
DCP signal service is initiated via the
bus
O (Red)
Error has occured
Ethernet/IP: Module status (MS)
O (Green)
Device in operation
Ö (Green)
Standby/device is not configured, no
IP address assigned
Ö (Red)
Warning, but device still operational
or firmware update
O (Red)
Error, device not operational
Ö ÖÖ(Green, red,
green)
Self-test when switching on
o
No supply voltage or no Ethernet/IP
app installed
3 PRODUCT DESCRIPTION
18
O P E R A T I N G I N S T R U C T I O N S | Inspector85x 8028305//2023-05 | SICK
Subject to change without notice

Table of Contents