Status LEDs
Display LED (color) Description
Ready
O (Green)
The device is switched on and ready
for use
O (Red)
Error
Ö (Green)
Device is not ready for use.
Reasons
•
Firmware update
•
Parameter change by the user
•
Parameter change by another
device (e.g., PLC)
O (Blue)
Device powers up
Result Red, green, blue, fuchsia,
yellow, aqua, white
Configurable by the user
Function Red, green, blue, fuchsia,
yellow, aqua, white
Configurable by the user
L/A P1 GbE Not used
L/A P2 GbE Not used
L/A P3 GbE
O (Green)
Connected to network
(10/100MB/s)
Ö (Green)
Data transmission over the network
(10/100MB/s)
O (Blue)
Connected to network (1GB/s)
Ö (Blue)
Data transmission over the network
(1GB/s)
o
No Ethernet connection
SF/RUN/MS PROFINET: System failure (SF)
o
No error
Ö (Red)
DCP signal service is initiated via the
bus
O (Red)
Error has occured
Ethernet/IP: Module status (MS)
O (Green)
Device in operation
Ö (Green)
Standby/device is not configured, no
IP address assigned
Ö (Red)
Warning, but device still operational
or firmware update
O (Red)
Error, device not operational
Ö ÖÖ(Green, red,
green)
Self-test when switching on
o
No supply voltage or no Ethernet/IP
app installed
3 PRODUCT DESCRIPTION
18
O P E R A T I N G I N S T R U C T I O N S | Inspector85x 8028305//2023-05 | SICK
Subject to change without notice