7
Focal length of lens, here example for f = 17.1 mm
8
Near range
Interpretation aid for the field of view diagram
Using the diagram, you can determine the following data for each device type:
•
The maximum working distance for a selected code resolution
•
The dimensions of the field of view that is available for this distance
7
0
200 x 160
400 x 320
600 x 480
800 x 640
1000 x 800
1200 x 960
0 200 400 600 800 1000 1200 1400 1600 1800 2000
a
b
Min. resolution in mm 3
1D code 4 2D code 5
0.4
0.6
0.8
0.1
0.3
0.5
0.7
0.9
1.1
1.3
0.2
1.2
1.4
1.6
1.0
a: f = 9.6 mm
b: f = 17.1 mm
Working distance/focus position in mm 6
Field of view in mm² 1
Complete area 2
8
9
ß
Figure 13: Interpretation aid for the field of view diagram
1
Field of view in mm
2
2
Overall range
3
Minimum resolution in mm
4
1D code
5
2D code
6
Working distance/Focus position in mm
7
Selected code resolution
8
Focal length of lens, here example for f = 9.6 mm
9
Reading off: resultant maximum working distance
ß
Reading off: resultant field of view (mm x mm)
Given (in red):
•
Code resolution 2D code 7: 1.0 mm
•
Focal length of lens 8: 9.6 mm
Read off (in green):
•
Maximum working distance 9: approx. 920 mm
•
Field of view ß: approx. 640 mm x approx. 510 mm
Both axes of the diagrams must be interpreted linearly.