It is not necessary to connect a computer with the SOPAS ET configuration soft‐
ware for transfer to the replacement device.
4 Transfer of the current configuration data by means of a download from the com‐
puter.
Prerequisite:
The configuration data of the device was saved on the computer. This took place
on completion of configuration of the device that is now to be replaced with the
SOPAS ET configuration software after confirmation by the user.
NOTE
For further information see "Initial commissioning", page 54.
Removing the device to be replaced:
CAUTION
Risk of injury due to hot device surface.
The surface of the device can become hot during operation.
■
Before commencing disassembly, switch off the device and allow it to cool down
as necessary.
NOTICE
Risk of damage to the memory card!
b
To avoid damaging the microSD memory card, make sure the device is de-ener‐
gized when you insert or remove the card. For this purpose, disconnect the device
from the supply voltage.
1. Switch off the supply voltage to the device that is to be replaced.
2. Mark the position and alignment of the device on the bracket or surroundings.
3. Disconnect and remove all connecting cables of the device.
4. Detach the device and remove from the bracket.
5. Backed-up configuration data: if an optional memory card was installed in the
device, remove the microSD memory card with the backed-up parameter set. The
memory card is located behind the side cover, see "Device view", page 15.
Putting the replacement device into operation:
1. Backed-up configuration data: install the optional microSD memory card from the
device that is to be replaced in the replacement device of the same type.
2. Mount and align the replacement device (see "Mounting", page 26). When doing
so, note the previously applied markings on the bracket or surroundings.
3. Reconnect the connecting cables of the replacement device (see "Electrical instal‐
lation", page 32).
4. Switch on the supply voltage for the replacement device.
✓
The replacement device starts with the default setting and searches for external
storage medium with a valid parameter set. Depending on the success of the
search, the replacement device proceeds as follows:
°
If the replacement device detects a memory card or the CM600 parameter
cloning module, the replacement device transfers the valid parameter set
from this storage medium to its permanent memory and operates in accor‐
dance with its configuration data.
°
If the replacement device does not detect any external storage media, the
replacement device will start with its last permanently stored parameter set.
In the case of devices that have not been used before, this corresponds to
the factory default setting.
9 TROUBLESHOOTING
62
O P E R A T I N G I N S T R U C T I O N S | Lector621 8022502/15NT/2020-02-11 | SICK
Subject to change without notice