Figure 39: Positions of the 16 scan layers, side view
1
Scan layer 1
2
Scan layer 6 (high resolution)
3
Scan layer 14 (high resolution)
4
Scan layer 16
10.2 Mechanics/Electronics
Connection type 2 x M12 round connectors
Supply voltage 9VDC ... 30VDC
Permissible residual ripple ±5%
Power consumption P
typ
= 10W
P
start
= 35W for 5s (motor start-up)
P
max
= 22W (with full specified current at all outputs)
Housing ALSi12
Optics cover: polycarbonate
Housing color Grey (RAL 7042)
Enclosure rating IP65, IP67, IP69K (DIN40050, Part 9)
Test conditions:
•
Water spray volume: 14l/min ... 16l/min
•
Water pressure/temperature: 10000KPa (100bar) / 80°C
•
Flat jet nozzle distance: 100mm ... 150mm
•
Spray angle: 0°, 30°, 60°, 90°
•
Cycle: 30seconds per position
•
Rotational speed of test specimen: 5rpm
TECHNICAL DATA 10
8027119/0000/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | multiScan136
55
Subject to change without notice