12 Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
www.sick.com/Ranger3
12.1 Product data
Device type code V3DR3-60NE31111 V3DR3-60NE21111S01
Part number 1091560 1083672
12.2 Features
Task Positioning, Inspection, Measuring
Technology 3D by Laser triangulation
Example field of view Free of choice by lens selection
Data synchronization Free running / Encoder triggered / Externally triggered
3D measurements Yes
Reflectance measure‐
ments
Yes
Scatter measurements Yes
Exposure modes Linear / HDR
ProFlex-Front Yes
12.3 Performance
Image sensor SICK CMOS with ROCC technology
Active imager size 15360 μm (H) × 4992 μm (V)
Sensor resolution 2560 px x 832 px
Pixel size 6 μm x 6 μm
Scan/frame rate 46000 3D profiles/s
Scan/frame rate full frame 7000 3D profiles/s
3D height resolution 16 bits, 1/16 subpixel
SNR
max
39.5 dB
Dynamic range 50 dB
Shutter type Global
Spectral range 400 nm ... 950 nm
12.3.1 Light sensitivity
The peak sensitivity is located in the interval from 600 to 650 nm.
TECHNICAL DATA 12