Figure 33: IP settings
2. To get suggested IP settings from the system, click GevDeviceProposeIP.
3. If needed, edit the suggested settings.
4. To save the IP settings, click GevDeviceForceIP.
5. Close the window.
6. To update the IP settings and the device status, click Scan.
Persistent IP-settings
Workflow step: Image, Data collection
1. Open the Parameter editor and go to the TransportLayerControl category.
2. In the GigE vision sub-category, select the GevCurrentIPConfigurationPersistent IP check
box and then edit the GevPersistentIPAddress, GevPersistentSubnetMask, and GevPersis‐
tentDefaultGateway parameters.
3. Re-start the camera to apply the updated parameters.
8.2.2 Adjusting focus
Workflow step: Image
When the camera is connected, look at the 2D image and the laser line and do the fol‐
lowing adjustments:
1. If needed, adjust the tilt of the camera so that the laser line is horisontal in the
image.
This is to make sure that the laser line appears along the sensor in the camera.
2. Turn the focus ring of the camera until the image is focused.
3. If needed, adjust the focus of the laser according to the instructions of the laser
manufacturer.
8.2.3 Recording images
Workflow step: Image, Data collection
8 OPERATION
54
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/14IM/2019-07 | SICK
Subject to change without notice