The last connected device is displayed in the 'Quick connect' list together with a bar
indicating the device status:
Device is available (or already connected).
Device is available, but the IP settings need to be modified.
Device is already in use.
1. If the suggested device is correct and available, click Connect.
2. If the suggested device is not correct or if the IP settings need to be modified,
a) Click More devices to go to the Cameras workflow step.
b) Click Scan to see all devices that are available on the network.
c) Select the correct device.
d) If needed, click IP settings and edit the non-persistent IP settings of the
device, see "Editing IP settings", page 53.
e) Click Connect.
✓
When the device is connected, the Image workflow step is displayed and the Para‐
meter editor opens.
3. In the Image workflow step, click Start to view the 2D images and the laser line.
8.2.1.1 Editing IP settings
Before you connect to the camera, you can set non-persistent IP address, subnet mask,
and gateway. These settings will be lost if the camera is restarted.
When you have connected to the camera, you can edit the corresponding parameters to
make the settings persistent, that is, save them in the camera's flash memory.
Non-persistent IP settings
Workflow step: Cameras
1. Select the correct camera and click IP settings.
✓
A new window opens.
OPERATION 8
8020774/14IM/2019-07 | SICK O P E R A T I N G I N S T R U C T I O N S | Ranger3
53