Chapter 3 Technical Information
RFID write/read device RFH630 (HF)
12 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014957/YSU6/2016-01-08
Electrical installation
3.2 Pin assignments
RFH630-1102101
RFH630-1000001
“Power/Serial Data/CAN/I/0” connection Male connector on the adapter cable
e.g. no. 2055419 (2 m)
CAN L
CAN H
TD+ (RS-422), HOST
TD– (RS-422),
TxD (RS-232), HOST
DC 10 V ... 30 V
TxD (RS-232), AUX
RxD (RS-232), AUX
RD+ (RS-422), HOST
GND
RD– (RS-422),
RxD (RS-232), HOST
Result 1 (switching output 1)
N. c.
N. c.
Result 2 (switching output 2)
7
6
Sensor 2 (switching input 2)
Sensor 1 (switching input 1)
SensGND
4
3
2
1
5
8
9
10
11
12
13
14
15
16
17
M12 male
connector,
A-encoded
CAN L
CAN H
TD+ (RS-422), HOST
TD– (RS-422),
TxD (RS-232), HOST
DC 10 V ... 30 V
TxD (RS-232), AUX
RxD (RS-232), AUX
RD+ (RS-422), HOST
GND
RD– (RS-422),
RxD (RS-232), HOST
Result 1 (switching output 1)
Result 2 (switching output 2)
7
6
Sensor 2 (switching input 2)
Sensor 1 (switching input 1)
SensGND
4
3
2
1
5
8
9
10
11
12
13
14
15
D-Sub-HD male connector
4
3
2
1
TD+
TD–
RD+
RD–
“Ethernet” connection
M12 female
connector,
D-encoded
4
32
1
6
1
10
5
11
15
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3
“Power/Serial Data/CAN/I/0” connection
CAN L
CAN H
TD+ (RS-422), HOST
TD– (RS-422),
TxD (RS-232), HOST
DC 10 V ... 30 V
TxD (RS-232), AUX
RxD (RS-232), AUX
RD+ (RS-422), HOST
GND
RD– (RS-422),
RxD (RS-232), HOST
Result 1 (switching output 1)
Result 2 (switching output 2)
7
6
Sensor 2 (switching input 2)
Sensor 1 (switching input 1)
SensGND
4
3
2
1
5
8
9
10
11
12
13
14
15
6
1
10
5
11
15
D-Sub-HD male connector