Chapter 3 Technical Information
RFID write/read device RFH630 (HF)
32 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014957/YSU6/2016-01-08
Electrical installation
3.7.7 Wiring the "Sensor 2" switching input in the CDB620-001 connection module
6
1
10
5
11
15
RFH630-1102101CDB620-001
PNP sensor
V
S
V
S
V
S
GND
GND
SensGND
3.32 K
6.64 K
Sensor 2
V
in
15
9
U
IN
* = DC 10 V ... 30 V
a) Sensor supplied by CDB620-001
b) Sensor connected electrically isolated/externally supplied
d) Switch connected electrically isolated/externally supplied
c) Switch supplied by CDB620-001
2
1
4
15
1
5
15
SGND
7
Shield
14
U
IN
*
13 Sens 2
Out
U
IN
*
GND
S3
e.g. photo-electric switch
CDB620-001
PNP sensor
V
S
GND
Connect the switch as shown in b)
15
SGND
7
Shield
14 U
IN
*
13 Sens 2
Out
U
IN
*
GND
S3
e.g. photo-electric
switch
Function assignment to "Sensor 2" switching input via SOPAS
("Sensor/Input 2):
- Start of reading clock
- Stop of reading clock
- Increment input
- If required further functions in the future
U
IN
*
CDB620-001
15 SGND
7 Shield
14
U
IN
*
13
Sens 2
GND
S3
ON
OFF
S3 : SGND-GND
ON
OFF
S3 : SGND-GND
ON
OFF
S3 : SGND-GND
V
S ext
Switch S3: SGND-GND
ON: GND of the sensor connected to GND
of CDB620-001/RFH630.
OFF: Sensor connected electrically isolated
to the CDB620-001/RFH630.
Reference potential valid for all switching
inputs ("Sensor 1/2" and "In 1/2")
Shield
D-Sub HD
male connector,
15-pin
M12 male
connector, 17-pin,
A-type encoded
cable, e.g. no. 2055419 (2 m)
GND
.
.
.
Shield
Shield
M12
female
connector,
17-pin
2
15
9
1
Signal
V
S
Sensor 2
SensGND
GND
Pin and wire color assignment of prefabricated cables
1) Cables no. 2049764 (0.9 m), no. 2055419 (2 m), no. 2055420 (3 m).
2) Cables no. 6042772 (3 m), no. 6042773 (5 m).
Cable
1)
Cable
2)
D-Sub HD
male
connector,
15-pin
1
4
15
5
M12
female
connector,
17-pin
2
15
9
1
Open end,
17 core
Blue
White-yellow
Red
Brown
V
in
= max. 32 V
Ratings for "Sensor 2" switching input
Power fed to the input starts the assigned
function, e.g. stop of reading clock.
[default setting: logic not inverted (active high),
debouncing 10 ms]
Optodecoupled, reverse polarity protected
Can be wired with the PNP output of a sensor
Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 32 V;
0.7 mA ≤ I
in
≤ 5 mA
Switching
behavior
Features
Electrical
values
17
16
10
11
12
15
14
6
5
4
13
7
8
9
1
2
3

Table of Contents