EasyManua.ls Logo

SICK RFH630

SICK RFH630
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Technical Information
RFID write/read device RFH630 (HF)
38 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014957/YSU6/2016-01-08
Electrical installation
3.7.13 Wiring the "External output 2" switching output in the CDB620-001 connection
module
Load (e.g. PLC)
GND
Quenching circuit:
Install an anti-surge
diode directly at the
load!
For inductive load:
V
out
RFH630
Serial Aux
(RS-232)
CDB620-001
U
IN
* = DC 10 V ... 30 V
CMC600
U
IN
*
The RFH630 indicates the switching status of its
logical "external output 2" via the serial Aux data
interface.
Software-controlled, the status is automatically
taken over by the CMC600 via the cable and
converted to the physical "Out 2" output in the
CDB620-001.
"External
output 2"
Ratings for "External output 2" ("Out 2“ switching output)
PNP switching against the supply voltage U
IN
*
[default setting: no function,
logic: not inverted (active high)]
Short-circuit proof + temperature protected
Galvanically not separate from U
IN
*
0 V ≤ V
out
≤ U
IN
*
(U
IN
* − 1.5 V) ≤ V
out
≤ U
IN
* with I
out
≤ 100 mA
Switching
behavior
Features
Electrical
values
24Out 2
22
GND
6Shield

Table of Contents

Other manuals for SICK RFH630

Related product manuals