Feature Parameter
Data transmission rate 20 kbit/s ... 1 Mbit/s
Protocol CSN (SICK CAN sensor network)
IO-Link
Number 1
Function IO-Link Master V1.1
Data transmission rate max. 230 kBaud
Digital switching inputs/outputs
IYI: Switching input, max. frequency: 30 kHz
IY2: Switching input/output (configurable), max. frequency: 30 kHz
FLEXBUS+ connection (SIM1000 FXG only)
Quantity 1 male connector on left, 1 female connector on right
Number of pins 10
Function Internal safety bus
11.3 Mechanics and electronics
Feature Parameter
Optical indicators 7 x status indicators, front membrane, red/green
4 x status indicators, front membrane, green
4 x status indicators, Ethernet, orange/green
Electrical connection Terminal block 1 - 4: spring terminals
Ethernet connections: RJ - 45
FLEXBUS+ connection: 10-pin male connector
Supply voltage 24 V DC, -30% / +25%
Operating current Must be limited by external power supply unit to max. 2 A
Power consumption Max. 10.5 W, without connected sensors
Power output Max. 9 W total (all connections)
Output current IY2 Max. 100 mA
Output current L+ 200 mA (400 mA briefly when switched on)
Housing material Polycarbonate
Housing color Light gray (RAL 7035)
Protection class III (EN 61140:2016-05)
Weight SIM1000 FXA: 430 g (with spring terminals)
SIM1000 FXG: 445 g (with spring terminals)
Dimensions (W x D x H) SIM1000 FXA: 67.5 mm x 120.6 mm x 106.7 mm
SIM1000 FXG: 73.5 mm x 120.6 mm x 106.7 mm
11.4 Ambient data
Feature Parameter
Electromagnetic compati‐
bility (EMC)
EN 61000-6-2:2005-08
EN 61000-6-4:2007 + A1:2011
Vibration resistance EN 60068-2-6:2008-02, EN 61131-2:2007-09
Shock resistance EN 60068-2-27:2009-05, EN 61131-2:2007-09
Electrical safety IEC 61010-1:2010 + COR:2011