!PPENDIX6+
6

#
' #
¬¬¬¬ª¬¬¬¬¬¬¬¬¬¬¬¬¬ª¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ª¬¬¬ª¬¬¬ª¬¬¬§
RelOP
FNoAbbreviation Meaning LED PCLSA
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
823RAR Zone Rel.zone extension for rapid reclosing R K/GK/G
824DAR Zone Rel.zone extension for delayed reclosing R K/GK/G
825Sync.Meas.St.start-to-measure signal for sync-check R K K
826RAR Only only rapid auto-reclosing allowed R
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
827DAR Only only delayed auto-reclosing allowed R
828DAR T-ACT.runDAR action time is running R K K
829DAR T-3p1 runDAR 3-pole dead time 1 is running R K K
830DAR T-3p2 runDAR 3-pole dead time 2 is running R K K
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
831DAR T-3p3 runDAR 3-pole dead time 3 is running R K K
832AR 1p in prog1-pole auto-reclose initiate K K
833AR 3p in prog3-pole auto-reclose initiate K K

«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
840Sync. off synchro-check function is switched off R K/GK/G
841Sync. runningsynchro-check function is running R K K
842Sync. faulty synchro-check function faulty R K K
843Sync.Tsup.Expsynchro-check supervision time expired R K K
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
844Sync.Overridesynchro-check programmed override R K/GK/G
845Sync. Synchrosynchro-check synchronism fulfilled R K/GK/G
846Sync. U1>U2< syn-check live line dead bus fulfilled R K/GK/G
847Sync. U1<U2> syn-check dead line live bus fulfilled R K/GK/G
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
848Sync. U1<U2< syn-check dead line dead bus fulfilled R K/GK/G

849Sync. Blockedsynchro-check function is blocked R K/GK/G

«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
850Sync. Releasesynchronism release (to ext. recloser) R K K
851Sync.CloseCmdclose command from synchro-check funct R K K

860Sync.Del. U> synchro-check delta U exceeded R K/GK/G
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
861Sync.Del. f> synchro-check delta f exceeded R K/GK/G
862Sync.Del.PHI>synchro-check delta PHI exceeded R K/GK/G

900Dev. Drop-offgeneral drop-off of the device (reset) K K
¨¬¬¬¬©¬¬¬¬¬¬¬¬¬¬¬¬¬©¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬©¬¬¬©¬¬¬©¬¬¬Á