AOP Operating Instructions – Issue 07/05
6SE6400-5AP00-0BB0
To upread a parameter set from an inverter to the AOP the following procedure
must be performed:
1. From the Main Menu scroll through the list of options using the
and
keys until ‘UPREAD’ is highlighted.
2. Press the
key to confirm the selected option.
The user is then presented with the Upread menu.
3. Press the
key to confirm or to cancel the process.
In Master mode the user would have to select a specific inverter from the
networked inverters.
4. Using the
and keys scroll through the parameter sets and
select the desired parameter set into which the information will be
written.
If the selected parameter set already contains a parameter set the user will be
given the option to clear the existing parameter set.
Pressing the and keys simultaneously when uploading will
delete the existing parameter set. When viewing stored parameter sets
this same key combination will display the software version number of
the uploaded parameter set.
The user will be presented with a confirmation screen.
5. Press the
key to confirm or to cancel the process.
The user will be presented with a ‘wait’ screen while communications with the
specified inverter is established.
Once communications have been successfully established and the upread is
proceeding, the user is presented with a further ‘wait’ screen.