Improperly
inserted memory
card when
updating software
1.
T
ur
n a
na
ly
ze
r po
we
r of
f.
2.
Re
mo
ve
th
e m
em
or
y c
ar
d.
3.
Ens
ure
tha
t t
he
lab
el
is
fac
ing
forward, with the arrows
pointing in and up.
4.
Re
in
se
rt
it
fi
rm
ly
.
When properly inserted, the
edge of the card is flush with the
analyzer case.
5.
T
ur
n a
na
ly
ze
r p
ow
er
on
.
Fixed platform
cannot be
installed
The moving table
is not in the
lowest position
1.
T
ur
n a
na
ly
ze
r p
ow
er
on
.
2.
Le
t th
e ana
ly
ze
r ini
ti
al
iz
e.
3.
Ign
ore
the
err
or
tha
t d
isp
lay
s.
4.
T
ur
n a
na
ly
ze
r po
we
r of
f.
5.
In
st
al
l th
e fi
xe
d pl
at
fo
rm
.
6.
T
ur
n a
na
ly
ze
r p
ow
er
on
.
7.
If y
ou a
re s
til
l un
abl
e to
ins
ta
ll
the fixed platform, contact your
local technical support
provider
.
Printout does not
contain all reports
Missing reports
are flagged for a
Confirmatory
Report, and Edit
flagged results is
On
When the run is complete, review
and edit the list of flagged reports.
When you exit the End-of-Run
Report screens, the reports are
printed.
Push bar does
not move to the
right after a strip
is placed onto the
platform
Other strips are
being moved
along the
platform
Allow up to 7 secon
ds to elapse
prior to movement of
the push bar.
The time lapse depends upon the
timing cycle for movement of the
strips across the
platform.
Strip sensor
problem
1.
Ens
ure
tha
t t
he
run
is
com
ple
te,
and the analyzer is at the
Ready/Run screen.
2.
T
ur
n a
na
ly
ze
r po
we
r of
f.
3.
W
ai
t
se
ve
ra
l
se
co
nd
s.
4.
T
ur
n a
na
ly
ze
r p
ow
er
on
.
5.
If
th
e p
ro
bl
em
co
nt
in
ue
s,
contact your local technical
support provider.
S
y
m
p
t
o
m
P
o
s
s
i
b
l
e
C
a
u
s
e
R
e
m
e
d
y

Table of Contents

Other manuals for Siemens Clinitek Advantus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Clinitek Advantus and is the answer not in the manual?

Siemens Clinitek Advantus Specifications

General IconGeneral
Test TypesUrinalysis
InterfaceRS-232, USB
CalibrationAutomatic calibration
Measurement PrincipleReflectance photometry
Sample TypeUrine
Power Supply100-240 VAC, 50/60 Hz
TypeUrine analyzer
DisplayTouchscreen
Reagent TypeTest strips
Measurement ParametersGlucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes