EasyManuals Logo

Siemens Clinitek Advantus Operator's Guide

Siemens Clinitek Advantus
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
C
l
i
n
i
t
e
k
A
d
v
a
n
t
u
s
O
p
e
r
a
t
o
r
s
G
u
i
d
e
9
5
S
t
m
C
o
n
f
i
g
u
r
t
i
o
n
3.
If
ne
ce
ss
ar
y
,
se
le
ct
Next Screen
to display an additional screen of tests.
4.
Wh
en
fi
ni
sh
ed
,
se
le
ct
Previous Screen
.
Normal Range for SG and pH
Y
ou can select
this option only if
Mark positives is
On.
Use this procedure to set the lower
and upper limits of the normal range for SG
and pH. Set each limit separately. The upper limit must be higher than or
equal
to the lower limit.
1
.
S
e
l
e
c
t
Normal range for SG/pH
.
2
.
S
e
l
e
c
t
t
h
e
+
or
-
keys next to each
limit to raise or lower the limit.
The limit changes by 1
reporting level until it is equal to the
opposite limit or
is at the highest or lowest reporting level.
3
.
S
e
l
e
c
t
Previous Screen
.
Normal Range for CRE
You can select this option only if you are using MULTISTIX PRO Reagent
St
rips and Mark
positives is On.
Use this procedure to select the lower and upper limits of the normal range for
creatinine. The upper limit must be equal to or higher than the
lower limit.
1
.
S
e
l
e
c
t
Normal range for CRE
.
2
.
S
e
l
e
c
t
t
h
e
+
or
-
keys next to each
limit to raise or lower the limit.
The number changes by 1
reporting level until it is equal to the opposite
limit or is at the highest or
lowest reporting level.
3
.
S
e
l
e
c
t
Previous Screen
.
Setup Menu 5
At the fourth Setup
menu, select
Next Screen
to access the fifth Setup menu.
M
e
n
u
O
p
t
i
o
n
D
e
f
a
u
l
t
Color
Determined
by
analyzer
C
o
l
o
r
c
h
o
i
c
e
s
Y
e
l
l
o
w
,
O
r
a
n
g
e
,
R
e
d
,
G
r
e
e
n
,
B
l
u
e
,
Brown, Other
C
l
a
r
i
t
y
c
h
o
i
c
e
s
C
l
e
a
r
,
S
L
C
l
o
u
d
y
,
C
l
o
u
d
y
,
T
u
r
b
i
d
,
Other
U
s
e
d
e
f
a
u
l
t
C
O
L
/
C
L
A
d
u
r
i
n
g
r
u
n
O
n

Table of Contents

Other manuals for Siemens Clinitek Advantus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Clinitek Advantus and is the answer not in the manual?

Siemens Clinitek Advantus Specifications

General IconGeneral
Test TypesUrinalysis
InterfaceRS-232, USB
CalibrationAutomatic calibration
Measurement PrincipleReflectance photometry
Sample TypeUrine
Power Supply100-240 VAC, 50/60 Hz
TypeUrine analyzer
DisplayTouchscreen
Reagent TypeTest strips
Measurement ParametersGlucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes

Related product manuals