EasyManuals Logo

Siemens CPU 313C User Manual

Siemens CPU 313C
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
Index
CPU 31xC and CPU 31x, Technical Data
Manual, 01/2006 Edition, A5E00105475-06
Index-3
R
RAM, 4-2
RAM to ROM, 4-12
Required basic knowledge, iii
Response time
Calculating the longest, 5-17
Calculating the shortest, 5-15
Conditions for the longest, 5-16
Conditions for the shortest, 5-15
Definition, 5-13
DP cycle times, 5-13, 5-14
Factors, 5-13
Fluctuation width, 5-13
Reduction with direct I/O access, 5-17
Sample calculation, 5-24
Restart, 4-13
Retentive memory, 4-2
Load memory, 4-2
Retentive behavior of memory objects, 4-3
Retentive behavior of the memory objects, 5-6
System memory, 4-2
Routing
Access to stations on other subnets, 3-11
Example of an application, 3-14
Network node, 3-11
Requirements, 3-13
S
S7 basic communication, 3-8
S7 communication, 3-8
S7 connections
Distribution, 3-30
End point, 3-28
of CPUs 31xC, 3-31
Time sequence for allocation, 3-29
Transition point, 3-28
Sample calculation
of the cycle time, 5-23
Sample calculation
of interrupt response time, 5-25
of the response time, 5-24
Scope of this documentation, v
Scope of this manual, A-1
SFB 52, 3-21
SFB 53, 3-21
SFB 54, 3-21
SFB 81, 3-21
SFC 49, 3-21
SFC 58, 3-20
SFC 59, 3-20
SFC 70, 3-21
SFC 71, 3-21
SFC102, 3-21
SFC13, 3-20
SFC5, 3-21
Shortest response time
Calculation, 5-15
Conditions, 5-15
SIMATIC Micro Memory Card
Plug-in MMCs, 6-2, 7-2
Properties, 4-8
Slot, 2-3, 2-6, 2-8, 2-10, 2-12
SNMP, 3-27
SSL, 3-23
W#16#0696, 3-23
W#16#0A91, 3-23
W#16#0C91, 3-23
W#16#0C96, 3-23
W#16#0x94, 3-23
W#16#4C91, 3-23
W#16#xy92, 3-23
Status displays, 2-13
System and Standard Functions, 3-20
System memory, 4-2, 4-4
I/O process image, 4-5
Local data, 4-7
T
Technical data
Analog inputs, 6-49
Analog outputs, 6-51
CPU 312C, 6-3, 7-3, 7-8, 7-13, 7-26, A-2
CPU 313C, 6-8
CPU 313C-2 DP, 6-26
CPU 313C-2 PtP, 6-14
CPU 314C-2 DP, 6-21
CPU 314C-2 PtP, 6-21
Digital inputs, 6-45
Digital outputs, 6-47
Technical Data
CPU 312C, 7-33, 7-40
CPU 313C-2 DP, 6-14
U
Upload, 4-11, 4-12
Useful life of an MMC, 4-9
User program
Upload, 4-11, 4-12
W
Warm start, 4-13
Watchdog interrupt, 5-22

Table of Contents

Other manuals for Siemens CPU 313C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 313C and is the answer not in the manual?

Siemens CPU 313C Specifications

General IconGeneral
MPI InterfaceYes
Number of digital inputs24
Number of digital outputs16
Number of analog inputs4
Number of analog outputs2
Supply voltage24 V DC
High-speed countersYes
Bit Operations Execution Time0.1 µs
Word Operations Execution Time0.2 µs
Power Consumption5 W
Dimensions (W x H x D)40 x 125 x 130 mm
Operating Temperature0 to 60 °C
Communication InterfacesMPI
Programming LanguagesLAD, FBD, STL
Product type designationCPU 313C
Weight490 g

Related product manuals