S7-300 Automation System, Hardware and Installation: CPU 31xC and CPU 31x
9-4 A5E00105492-03
 &RPPLVVLRQLQJ&KHFNOLVW
,QWURGXFWLRQ
After you have mounted and wired your S7-300, we recommend you check all
previous steps once again.
The checklist tables below are a guide for your examination of the S7-300. They
also provide cross-references to chapters containing further information on the
relevant topic.
0RGXOHUDFNV
3RLQWVWREH([DPLQHG 6+DUGZDUHDQG
,QVWDOODWLRQ&KDSWHUV
Are the rails mounted firmly to the wall, in the frame or in
the cabinet?
Configuring, Installation
Have you maintained free space required? Configuring, Installation
Are the cable ducts installed properly? Configuring
Is the air convection OK? Installation
&RQFHSWRIJURXQGLQJDQGFKDVVLVJURXQG
3RLQWVWREH([DPLQHG 6+DUGZDUHDQG
,QVWDOODWLRQ&KDSWHUV
Have you established a low-impedance connection
(large surface, large contact area) to local ground?
Configuring, Appendix
Are all racks (rails) properly connected to reference
potential and local ground (electrical connection or
isolated operation)?
Configuring, Wiring, Appendix
Are all grounding points of electrically connected
modules and of the load power supply units connected
to reference potential ?
Configuring, Appendix
0RGXOHLQVWDOODWLRQDQGZLULQJ
3RLQWVWREH([DPLQHG 6+DUGZDUHDQG
,QVWDOODWLRQ&KDSWHUV
Are all modules properly inserted and screwed in? Installation
Are all front connectors properly wired, plugged, screw-
tightened or latched to the correct module?
Installation, Wiring

Table of Contents

Other manuals for Siemens CPU 315-2 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 315-2 DP and is the answer not in the manual?

Siemens CPU 315-2 DP Specifications

General IconGeneral
Memory64 KB
Power Supply24 V DC
Order Number6ES7 315-2AG10-0AB0
Number of DP Masters1
Number of DP Slaves124
Load Memory64 KB
Number of Timers256
Number of Counters256
Data Memory64 KB
Operating Temperature0 to 60 °C
Integrated InterfacesMPI, DP
Digital OutputsNot integrated
Analog InputsNot integrated
Analog OutputsNot integrated
Programming LanguagesLAD, FBD, STL
Digital InputsNot integrated
Weight660 g