S7-300 Automation System, Hardware and Installation: CPU 31xC and CPU 31x
13-12 A5E00105492-03
3URJUDPPDEOHFRQWUROOHU
Programmable controllers (PLCs) are electronic controllers whose function is
saved as a program in the control unit. The configuration and wiring of the unit are
therefore independent of the function of the control system. The PLC has a
computer structure; it consists of the Æ CPU (Central Processing Unit) with
memories, I/O modules and internal bus system. The I/Os and the programming
language are oriented to control engineering needs.
5$0
RAM (Random Access Memory) is a semiconductor read/write memory.
5HIHUHQFHJURXQG
Æ Ground
5HIHUHQFHSRWHQWLDO
Potential with reference to which the voltages of participating circuits are observed
and/or measured.
5HWHQWLYLW\
A memory area is retentive if its contents are retained even after a power failure
and a change from STOP to RUN. The non-retentive area of memory markers,
timers and counters is reset following a power failure and a transition from the
STOP mode to the RUN mode.
The following can be made retentive:
flag bits
S7 timers
S7 counters
Data areas
5HVWDUW
On CPU startup (e.g. after is switched from STOP to RUN mode via selector switch
or with POWER ON), OB100 (restart) is initially executed, prior to cyclic program
execution (OB1). On restart, the input process image is read in and the 67(3
user program is executed, starting at the first instruction in OB 1.
5XQWLPHHUURU
Errors occurred in the PLC (that is, not in the process itself) during user program
execution.

Table of Contents

Other manuals for Siemens CPU 315-2 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 315-2 DP and is the answer not in the manual?

Siemens CPU 315-2 DP Specifications

General IconGeneral
Memory64 KB
Power Supply24 V DC
Order Number6ES7 315-2AG10-0AB0
Number of DP Masters1
Number of DP Slaves124
Load Memory64 KB
Number of Timers256
Number of Counters256
Data Memory64 KB
Operating Temperature0 to 60 °C
Integrated InterfacesMPI, DP
Digital OutputsNot integrated
Analog InputsNot integrated
Analog OutputsNot integrated
Programming LanguagesLAD, FBD, STL
Digital InputsNot integrated
Weight660 g

Related product manuals