25 / 96
BA 5030 en 02/2013
4.4.1 Interior preservation with preservative agent
Table 9: Durability period and measures for interior preservation when using mineral oil or PAObased
synthetic oil
Duration of protection
Preservative agent Special measures
up to 6 months
Castrol Alpha SP 220 S
none
up to 24 months
- Close all holes in the gear unit
Replace air filter with screw plug.
(prior to startup replace screw plug
with air filter)
For storage periods longer than 24 months, renew the preservative agent.
For storage periods longer than 36 months, Siemens should be consulted before.
Table 10: Durability period and measures for interior preservation when using PGbased synthetic oil
Duration of protection
Preservative agent Special measures
up to 6 months
Special anticorrosion oil
TRIBOL 1390
1/
none
up to 36 months
- Close all holes in the gear unit
Replace air filter with screw plug.
(prior to startup replace screw plug
with air filter)
For storage periods longer than 36 months, Siemens should be consulted before.
1)
Resistant to tropical conditions and sea water; max. ambient temperature 50 °C
4.4.2 Exterior preservation
Table 11: Durability period for exterior preservation of shaft ends and other bright machined surfaces
Duration
of protection
Preservative
agent
Layer
thickness
Remarks
in case of indoor
storage
up to 36 months
1)
Tectyl 846 K19 approx. 50 μm
Longterm waxbased preservative
agent:
- resistant to seawater
resistant to tropical conditions
(soluble with CH compounds)
in case of outdoor
storage
up to 12 months
2)
1)
The gear unit must be stored in the position of use in a sheltered place; it must be placed on
a vibrationfree, dry wooden base and covered over.
2)
If the gear unit is being stored out of doors, it must be particularly carefully covered, and care must be
taken that neither moisture nor foreign material can collect on the unit. Waterlogging should be avoided.
The procedure for interior and exterior preservation treatment is described in section 7
(see items 7.3.1.3 and 7.3.2.1).