EasyManua.ls Logo

Siemens FLENDER H SH Series - Re­mounting the Shrink Disk; Inspection of the Shrink Disk

Siemens FLENDER H SH Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63 / 96
BA 5030 en 02/2013
Use a solid lubricant paste with a high MoS
2
based molybdenum disulphide content which will
not slide during fitting work and which shows the following characteristics:
Friction coefficient "μ" = 0.04
Resistant to pressure up to a maximum pressure of 300 N/mm
2
Ageingresistant
Table 19: Recommended lubricants for shrink disks after their cleaning
1)
Lubricant Form Manufacturer
Molykote G Rapid Spray or paste DOW Corning
Aemasol MO 19 P Spray or paste A. C. Matthes
Unimoly P 5 Powder Klüber Lubrication
gleitmo 100 Spray or paste Fuchs Lubritec
1)
Other lubricants may be used if they have the same characteristics.
Join inner ring (3) and outer ring (4).
Place the tensioning bolts and screw in some threads by your fingers.
Observe the manufacturer’s instructions for handling lubricants!
Mounting and startup must be carried out by properly trained specialist personnel.
6.7.4 Remounting the shrink disk
For remounting the shrink disk the procedure described in item 6.7.1 must be adhered to.
6.7.5 Inspection of the shrink disk
In all cases the inspection relating to the shrink disk should be carried out simultaneously with
the examination of the gear unit, however at least every 12 months.
Inspection of the shrink disk is limited to a visual assessment of its condition. The following must be
observed when carrying out this work:
loose screws
damage caused by force
flush position of the inner ring (3) in relation to outer ring (4)

Table of Contents