67 / 96
BA 5030 en 02/2013
6.11 Mounting the torque arm for the gearunit housing
6.11.1 Attaching the torque arm
The torque arm must be mounted stressfree on the machine side
On helical gear units with a motor bell housing the torque arm is located opposite the motor bell housing.
1
2
Fig. 55: Torque arm for gearunit housing
1 Machine side 2 Flexible support block
Table 22: Motor types and torque arms
Gearunit size
Max. perm. standardmotor size
Gear type Gear type
H2 H3 H4 B2 B3 B4
4 200 - - 200 200 -
5 ... 6 225 225 - 225 225 160
7 ... 8 280 280 180 280 280 200
9 ... 10 280 280 225 280 280 225
11 ... 12 315M 315M 250 315M 315M 280
13 ... 14 - 355 315M 355 355 315M
15 ... 16 - 355 315 - 355 355M
17 ... 18 - 355 355M - 355 355
19 ... 22 on request
Larger motors should be used only with approval of Siemens.
• For realising the foundation for fastening the torque arm, see item 6.3.1 (Foundation).
• If the customer fits a torque arm, connection to the foundation must be by means of a flexible element.