BA 5030 en 02/2013
7.2.7 Checking procedure
The following visual checks must be conducted and recorded when starting up:
Presence of explosionprotection marking
Oil level
Leaktightness of the oilcooling or oilsupply lines
Opening condition of the shutoff valves
Effectiveness of the shaft seals
The tension pressures and/or pretensioning forces in accordance with item 6.3.2.4 must also be recorded
in this document.
The document must be kept with the instructions.
7.3 Removal from service
Switch off drive unit.
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch!
In the case of gear units fitted with cooling coil or water oilcoolers, close the stop valves on the water
in and outflow pipes. To prevent freezing, drain the water from the cooling coil or the water oilcooler.
Start the gear unit and allow it to run briefly (5 to 10 minutes) approx. every 3 weeks (during a shutdown
period no longer than 6 months).
Treat the gear unit with preservative, see items 7.3.1 and 7.3.2 (before a shutdown period exceeding
6 months).
7.3.1 Interior preservation during longer disuse
Depending on the type of lubrication and/or shaft sealing, the following types of interior preservation can
be applied.
7.3.1.1 Interior preservation with gear oil
Gear units with splashlubrication systems and contacting shaft seals can be filled with the correct type of
service oil up to a point just below the air filter.
7.3.1.2 Interior preservation with preservative agent
Before longer shutdown periods gear units with forced lubrication systems, oil-circulation cooling and/or
noncontacting shaft seals should be filled with preservative agent and run without load.