BA 5030 en 02/2013
H1.. / H2.. ≤ 12 H1.. / H2.. ≥ 13
5
1
2
6
1
2
6
5
3
4
Fig. 23: Air oilcooling system on gear units types H1.. and H2..
B2.. ≤ 12 B2.. ≥ 13
5
1
2
6
1
2
6
5
3
4
Fig. 24: Air oilcooling system on gear units type B2..
1 Flange pump 4 Double changeover filter
2 Pressure monitor 5 Air oilcooler
3 Coarse filter 6 Temperaturecontrol valve
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
When installing the gear unit with an addon air oilcooler, it must be ensured that the
air circulation is not obstructed.
The required minimum distance from adjacent components, walls, etc. is indicated in
the drawings in the unit documentation.
Depending on the application, the flange pump may have been replaced with a motor pump.
When operating and servicing the components of the oilsupply system, observe the
operating instructions of the components.
For technical data, refer to the data sheet and/or the list of equipment.
The cooling effect is considerably reduced if the cooler or the gear housing are dirty (see section 10,
"Maintenance and repair").