BA 9142 en 02/2015
Original storage place of the gear unit
In which climatic zone is the construction site
located?
Setup in climatic zone B and/or less than 50 km
distance from larger bodies of salt water
How was the gear unit packaged for transport? None or simple
transport packaging
Transport in
seaworthy packaging
2)
How was the gear unit transported? without sea transport with or without sea transport
In what packaging was the gear unit stored at the
construction site?
no packaging seaworthy packaging
2)
Where/how was the packed unit stored?
in closed room
or
under roof
1)
covered with
loose tarpaulin
in closed room
or
under roof
1)
exposed
outdoors
or
covered with
loose tarpaulin
Change of storage
New
packaging for
storage
Storage place of
the newly
packaged unit
Change of
original
storage
method after
durability period of interior preservation of the gear unit for the new
storage method in consideration of the previous storage period in months
without
packaging
exposed
outdoors
1 month 2 1/2 2 3 3
3 months 2 1 2 1/2 2 1/2
6 months 1 1/2
not permissible,
max. durability
period 4 months
2 2
12 months
not permissible,
max. durability
period
11 months
not permissible,
max. durability
period 4 months
1 1/2 1
18 months
not permissible,
max. durability
period
11 months
not permissible,
max. durability
period 4 months
1 1/2
covered with
loose tarpaulin
exposed
outdoors
1 month 3 1/2 3 5 5
3 months 3 1 4 1/2 4
6 months 2
not permissible,
max. durability
period 4 months
4 3 1/2
12 months
not permissible,
max. durability
period
11 months
not permissible,
max. durability
period
4 months
2 1/2 2
18 months
not permissible,
max. durability
period
11 months
not permissible,
max. durability
period
4 months
1 1/2 1/2
1) under roof:
no direct exposure to sunlight and no direct contact with water (rain or draining water)
2) Seaworthy packaging:
use of wooden box lined with bitumen paper. The content is sealed in foil and protected against moisture by
addition of drying agents for the prescribed storage period.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Flender KMPP Series and is the answer not in the manual?

Siemens Flender KMPP Series Specifications

General IconGeneral
BrandSiemens
ModelFlender KMPP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals