EasyManuals Logo

Siemens FLENDER PLANUREX 2 PBUC Series User Manual

Siemens FLENDER PLANUREX 2 PBUC Series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22 / 55
BA 9213 en 03/2012
5.2.7.2 Starting when the bucket wheel is at a standstill
The bucket wheel must have reached equilibrium.
Release brake.
Start pump.
After 10 minutes start main motor and/or auxiliary motor.
5.2.7.3 Changeover from main to auxiliary drive
Switch main motor off .
Leave pump on.
Close brake.
Engage auxiliary gear.
Release brake.
Start auxiliary motor.
5.2.7.4 Safety "Off" (emergency stop)
Switch off main motor and/or auxiliary motor, depending on type of operation.
Close brake.
5.2.8 Auxiliary drive (optional)
The bucket wheel drive may optionally be provided with an auxiliary drive. This auxiliary drive enables the
gear unit to be operated at a lower output speed in the same direction of rotation. The auxiliary drive is
connected with the gear unit by a clutch.
Main and auxiliary motors must not be started together.
The auxiliary drive should be protected against overload.
The auxiliary drive serves as a drive during maintenance, installation and repair work.
1
3
2
Fig. 5: Auxiliary drive components
1 Auxiliary drive 2 Shift lever 3 Limit switch
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens FLENDER PLANUREX 2 PBUC Series and is the answer not in the manual?

Siemens FLENDER PLANUREX 2 PBUC Series Specifications

General IconGeneral
BrandSiemens
ModelFLENDER PLANUREX 2 PBUC Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals