10.2.3 Cleaning the air filter
If a layer of dust has built up, the air filter must be cleaned, whether or not the minimum period
of 3 months has expired.
Unscrew the air filter including the reducing screw.
Clean the air filter using benzine or a similar cleanser.
Dry the air filter and/or blow with compressed air.
Be especially careful when blowing with compressed air.
Wear protective glasses!
Foreign bodies must be prevented from entering the gear unit.
10.2.4 Cleaning the breather screw
If a layer of dust has built up, the breather screw must be cleaned, whether or not the minimum
period of 3 months has expired.
Unscrew breather screw.
Clean the breather screw using benzine or a similar cleanser.
Dry the breather screw and/or blow with compressed air.
Be especially careful when blowing with compressed air.
Wear protective glasses!
Foreign bodies must be prevented from entering the gear unit.
10.2.5 Cleaning the gear unit
To prevent the buildup of dust on the gear unit, cleaning must be done in accordance
with operating conditions.
Remove any dirt adhering to the housing with a hard brush.
Remove any corrosion.
The outside of the gear unit must not be cleaned with highpressure cleaning
equipment.
10.2.6 Refilling Taconite seals with grease
Inject approx. 30 g lithiumbased bearing grease into each of the lubrication points of the Taconite seal.
The lubrication points are fitted with flat grease nipples type AM10x1 to DIN 3404.
Remove and dispose of any old grease escaping.
10.2.7 Checking oil cooling system
Close the stop valves in the coolant in and outflow pipes.
Inspect cooler for leaks in the water conducting piping.
Check the condition of screw connections and, if necessary, replace.
For operation and maintenance, always observe the operating instructions indicated in the
orderspecific appendix.
For technical data, refer to the orderspecific list of equipment.