31 / 55
BA 9213 en 03/2012
6.6.2 Demounting the type HYD shrink disk
• Remove the protective cover.
• Remove screw plugs from the "Clamp" and "Release" connections.
Collect any hydraulic fluid that may run out!
• Connect the oil pressure pump to the connection marked "Clamp".
• Increase the oil pressure (max. 450 bar) until the lock nut can be loosened by hand.
• Relieve pressure and attach pump to connection marked "Release".
• While the oil pressure is increasing, the outer ring will slip off the cone of the inner ring. The connection
is disengaged again.
• Leave hydraulic fluid in the released shrink disk and firmly reseal the "Clamp" and "Release"
connections with the screw plugs.
• Remove the machine shaft or slide the gear unit off the machine shaft. Rust deposits which may have
formed on the shaft must be removed before performing this operation.
• Pull the shrink disk off the hollow shaft.
6.6.2.1 Cleaning and greasing the type HYD shrink disk
Released shrink disks do not have to be disassembled and regreased before being reclamped.
The shrink disk should only be disassembled and cleaned if it is dirty.
Following cleaning, only the inner sliding surfaces of the shrink disk should be
regreased.
Use a solid lubricant with a high MoS
2
based molybdenum disulphide content and with a coefficient of
friction of μ = 0.04 according to the following table.
Table 8: Lubricants for shrink disk after cleaning
Lubricant
Form Manufacturer
Molykote 321 R (lubricating paint) Spray DOW Corning
Molykote Spray (powder spray) Spray DOW Corning
Molykote G Rapid Spray or paste DOW Corning
Aemasol MO 19 P Spray or paste A. C. Matthes
Molykombin UMFT 1 Spray Klüber Lubrication
Unimoly P 5 Powder Klüber Lubrication
6.7 Installation of the torque arm
For all shaft-mounting gear units, the reaction torque corresponding to the torque of the
machine and acting in an opposite direction on the housing must be absorbed.
6.8 Gear unit with motordriven oil pump
• Wire the motor electrically.
• Wire the double changeover filter electrically.
• Wire the pressure monitor electrically.
• Wire the volumeflow meter electrically.
If a terminal box is delivered attached to the unit, the electrical leads to the devices are already wired up
in the terminal box.