7. Startup
Observe the instructions in section 3, "Safety instructions"!
7.1 Procedure before startup
7.1.1 Removal of preservative agent
Unscrew and open oil drain plug and drain remaining preservative agent or runningin oil from the
housing into a suitable container and dispose of in accordance with regulations. Any residualoil drain
plugs should also be opened. The location of the oil draining point is marked by an appropriate symbol
in the dimensioned drawing in the gearunit documentation.
Remove any oil spillage immediately with an oilbinding agent.
Screw the oil-drain plug in.
1
2
3
4
Fig. 9: Oil inlet/oil drain gear unit
1 Inspection cover / oil inlet 3 Air filter
2 Oil dipstick 4 Oil-drain plug
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
Before startup, replace the yellow plastic plug with a breather screw with cap
(see also notice on gear unit).
The oil must not come into contact with the skin (e.g. the operator’s hands).
The safety notes on the data sheets for the oil used must be observed here!