HiPath1120, Installation Guide
3-19
Installation
Installing modules
3.7.3 Installing modules
3.7.3.1 On the HiPath 1120
Installation Procedures
Step Procedure
1. Turn off the power supply.
2. Remove the systems cover
3. Insert the module into one of the slots shown in figure 3-5.
4. Underside: To install the LAN Interface Module or Music Module, lift the top part
(MB) of the system and use the pin bar to connect with X1 position of the LAN
Interface Module or X2 position of the Music Module.
5. Top side: Interconnect the module and the MB using the flat cable/s provided, taking
care to pass it through the ferrite (see figure 3-5).
6. Connect to the module’s MDF Connectors (see figure 3-14).
7. Reassemble the entire set.
8. “Performing a visual inspection” on page 3-35.
9. Turn on the power supply.
10. Configure the required data (see Service Manual).
11.
*
* This is necessary only if you have changed the type of the modules installed in your system.
Using Manager application go to: Advanced tab, > PBX Information tab, > Slot
Allocation tab;
Select the Clear All Slots checkbox;
Update the HiPath System;
Reset the HiPath System.